what are the disadvantages of leading P.F(power factor)?

Answer Posted / natha

pf leading or lagging both are undesired.practice generally is to maintain near unity pf which means full utilization of power generated.
If a purely resistive load is connected to a power supply, current and voltage will change polarity in step, the power factor will be unity (1), and the electrical energy flows in a single direction across the network in each cycle. Inductive loads such as transformers and motors (any type of wound coil) consume reactive power with current waveform lagging the voltage. Capacitive loads such as capacitor banks or buried cable generate reactive power with current phase leading the voltage. Both types of loads will absorb energy during part of the AC cycle, which is stored in the device's magnetic or electric field, only to return this energy back to the source during the rest of the cycle.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the relationship between current&voltage in practical purpose ?

4263


how to check three phase motor torque value?

1728


What is electrical cable termination

2211


Why compensation is necessary in feedback control system?

763


how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you

1507






what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor

1646


Dyn1 transformer vector group testing how to do

1319


What is the distance between each insulator in 33kv transformer and how can it calculate

1747


hi frds, i m electrical engineer.can i get cdr for electrical engineer if u have then send me on my mail id its jayesh_ee88@yahoo.com.please help me frds

1605


How to decide the size of the capacitor for a single phase induction motor say 2 HP ??

1638


sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)

1556


explain different types of d.c motors?

703


what are the stresses in circuit breakers ?

1511


list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.

1547


What are all present producing cost of Per KWH of various Fuel?

2108