Answer Posted / a.c.subash
Calibration is the calibrating the instrument with the
Master Instrument which is calibrated against National
Standards and the Value is fed in the Test Instrument.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What materials are used in thermo wells?
How u measure the massflow in orifice flow measurement techniques
sir, give me placement papers and interview quistion of birla group company of copper.
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
how many types of viberation transmitter and how to calibrate and where use of vibration transmitter
what is the reason while warning lamp is on while the engine is cranking?
Explain the key components of control loop?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.