Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why material of brush is carbon in motors why not other
material.

Answer Posted / keepup

as per my limited knowledge i think the reaso y brush is
made of carbon is coz carbon has a negative temperature
coeficient of resistance, that is due to friction between
the brush and rotor, temperature is developed. as a result
the resistance of carbon brushes will decrease. for
instance if copper or aluminum brush is use, then when temp
increases at the contact pt between the brush and rotor,
resistance of the copper or aluminum brush will increase
resulting in loss of energy usually in the form of heat and
may lead to burning of the brushes.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please describe the Transformer setting, Motor setting, I/C setting, Tie setting

1834


What happen if 200 KVAR capacitor connected to power continuesly?

2175


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2201


How to decide and select the different earthing wire size for the different types of earthing

2334


errection check list for transformer maintenance

2657


In Generator How suction compression power and exhaust works ?

1998


Why cables and busbar both needed in LT Panels?

2237


what is the VA(Volt-amphere)? define with calculation?

1345


boiler is running in rankine cycle and deisel generator is....?

2101


As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?

1911


How to measure the Harmonic Distortion of UPS ie THD?

2417


Differentiate between real and apparent power?

1218


hi, i finished b.tech eee in 2008, im worked in dg sets mfg company , now i left job in 6months back, now again i want get job core side, how can i get? is there any couses we have learn to get better oppurtunity? /

2034


what is the significance of terminal voltage and phase sequence in the operation of paralleling of two generators?

2592


Can anyone explain me about the RLC based Impulse high voltage generator and how to and operation of Series resonant High voltage reactor...?

1992