Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are different types of excitation in synchronous
generator,what is the difference between them

Answer Posted / lashari

In the small Generators the batteries are used for excitation while in big generators the excitor in built in machine on the rotor of generator which is dc small generator to provide excitation current. so there are two types of excitation i) seperately excited and self excited discussed later..
www.bestarticlez.com

Is This Answer Correct ?    2 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the voltages using in movie theaters??? why ??why not other??

2278


Why are the laminations insulated from each other?

1140


pre arcing time of ehv breaker

2117


WHAT IS IEC? & WHAT IS BENEFIT TO PRODUCT FROM IEC?

2115


which capacity of RCCB used for five thousand watt electricity load?

1854


Why 11kv to be generated in generation station

1651


What is measurement?

1170


what is smartµ grid technology?under coal gassification?

1939


What is difference between insulating medium and fault current interruption medium in a switching device.

1632


why single phase to grd test in HV cable?why not 2 phase at a time?

2274


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2016


What is dielectric loss?

1120


What is state space method ? Why its used ? Can it applicable on linear, non-linear, 1st order, higher order, homogeneous, non-homogeneous, open-loop , closed loops , stable & unstable systems ?

2024


If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer

2690


During underground cabling in landscape area what did we cover the cable with to prevent the electric shock & protect the cable?

1845