Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How check proper electrical earthing of machine.

Answer Posted / k.cs

This method of checking is ok,but there is a chance of
electrical shock may be felt by testing person by mistake.
Hence it is always advisable to test at electrical socket
with out connecting machine in the socket, that is there
willbe a 1-3 voltages should be in between neutral and
earth points.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.

2260


which type of amplifiers are used in multimete?

2270


What is the basic principle of operation of alternators/dc generators?

1146


A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why

2013


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2506


Define unilateral circuit?

1319


What is difference between Sample test and Routine test in safety standard?

1987


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

2068


can we do the star delta connection of capacitor for 3- phase motor starter.

2081


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


What is “pu” in electrical engineering?

1195


what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

2245


A cotter joint is generally used to transmit

1309


How the setting of the vector surge relay shall be calculated when the relay is to be used for Grid islanding application?

2304


size of condotory fron voltage level

2262