Explain why machinery used on a.c supply is usually rated
in KVA instead of KW?

Answer Posted / manugirl

t is because machinery used on ac supply are transformer regulated and the certainty that transformers are rated in KVA so as machineries used on ac supply should be given contained by KVA rating.
AC supply machines are rate in KVA . The total power consumed or supplied by the system depend up on the power factor of the load. As you know KVA= KW / Power factor.KW will cash for power factor.

Also size of a AC system is depend up on the insulation requirement (depend upon voltage) and size of conducting material( depend upon the current) so Voltage x current will give VA or Size of AC system
All AC power sources like transformers, generators, inverters etc. are usually rate in KVA.

The reason is that surrounded by the case of a power source, you cannot predict the type of load (resistive, Capacitive or Inductive) that will be connected to it. Hence the actual usable size rating depends on the power factor of the load.

Power = Voltage x Current x Power Factor

If the load is resistive, PF is 1 (unity) and if the nouns is inductive, it will be less than unity.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the role of Dedicated earthing in UPS System?

2640


where can the transformer having vector group Yny0 be used??

3595


A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.

627


explain Density

654


How you will determine the volume of oil in a particular Distribution transformer.

1445






What is hipot test procedure?

1015


State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

1477


What is the effect of pd controller on system performance?

647


what is your majour contributions in your present job

1344


We normally make oil soak pits under Transformers. Oil from soak pit goes to collection pit. We provide granules/pebbles under transformers. My question is weather granules/ pebbles to be filled in soak pit or not? if yes upto what level?

9888


If a air condition consume 2.50 to 3.00 amp then how much it will consume in watts if it is running 10 hours out of 24 hours????

1456


why the perameters of secondary circuit are more important then that of the primary circuit of induction motor?

1379


define hysteresis loss, eddy current loss and windage loss

1538


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1396


what will be d.g. capacity to cater together for 14hp A.C. load & 3kw lighting load

1557