Between Star-Delta & Star-Star Power transformer which one
is efficent for Earth Fault?

Answer Posted / sunil guru

Star - Star bcz.. it has a point at center which can be
used as a neutral or can be grounded,
but in case of star-delta there is no path for ground
return current during short circuit..an the circulating
current will flow inward itself and can damage the winding..

for any disagreement mail me at parmar20072008@yahoo.com

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is invertor supply and raw powersupply

1518


what is the necessity of under ground cables ??

1619


Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?

1522


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

5582


what is the illumination level required for child play area?

1608






why can the rotor of 3 phase slip ring induction motor not be a 2 phase rotor?

1555


we have 15 ampere variyac but we want 30 ampere variyac what we do

1418


What is the difference between the impedance percent and impedance voltage ?

1688


what will happens if one phase is missing for 33/11kv power transfomer and why?

2183


Refernce currents are to be generated using refernce cueernts how can this be done??

1561


why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.

1404


what you have to see after one week or month from the day of installation of transformer ?

1223


Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.

1533


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1570


What is the principle of HIGH SPEED DIRECT DRIVE MOTOR ?

1510