my company total load is 1000kw, 415volt, all load are
inductive load. incoming powerfactor is .8. we want to
have0.95 pf connecting capacitors. so now how much rating of
capacitors we have to connect? show how?
Answer Posted / rsundareee
your original p.f is 0.8(Tan 0.8) and you required p.f is
0.95(Tan 0.95).Required p.f = kW(Tan0.8 - Tan 0.95),when
you select the breaker rating of Capacitor bank you have to
conside the Hormonics (33%),For exambe breaker rating will
be 100A it shall be (100+33=133) 160A MCCB.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
how to decide choke rating for drive?
Why is tan-delta test and capacitor measurement done on alternator?
Hello seniors m an engineering student in 3rd yr..i want to know what are the software course in electrical field?i wanted to do certification course but i dont know much about the course?..Regards
we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?
what is servo motor & how does it work.
Diagram on interconnectivity of 11kv transformer with RMU (i.e, one incoming and two outgoing or two incoming and one outgoing)
Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph
What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.
What is meant by Load Encroachment in OHL Feeder Protection?
Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP
What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan
what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?
DEAR SIR/MADAM,CLEARLY EXPLAIN ABOUT CRAWLING AND COGGING EFFECTS IN INDUCTION MOTOR.
How delta connection in the primary of distribution transformer reduces harmonics?how delta connections reduces harmonics?Please answer me...Hope that question is correct.