Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

3. What is Impedance Voltage in Transformer?

Answer Posted / madhu

Impedance voltage of a transformer is the voltage required

to

short circuit the secondary winding terminals of the
transformer and apply voltage gradually from zero at
primary winding.increase the voltage gradullay till the

full load current flows in the secondary.The voltage at

which full load current flows that voltage is the impedance

voltage of the transformer.This is required for short
circuit calculations.You can find on the transformer name

plate as Impedance voltage or percentage impedance

Is This Answer Correct ?    27 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?

2160


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

2084


As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.

1843


What are the application of filter?

1118


I use 20 nos led tube 4feet, in pathway 100mtr approximate, so what size cable i use for lighting

1512


what is the carona effects meaning in HT line transmmission system

2070


operation of diesel generator

2077


how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

2010


what is W.T?specify the acceptable range?

2013


Can we Co-ordinate relay in Load Break switch?

2026


Why is a synchronous motor always star connected??

2650


how to select fuse rating for a 3-phase motor ???

1846


i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors

1900


why we use single core 630mm2 cable for transformer secondary side

971


How cmd is calculated in case of energy neters

1997