3. What is Impedance Voltage in Transformer?
Answer Posted / madhu
Impedance voltage of a transformer is the voltage required
to
short circuit the secondary winding terminals of the
transformer and apply voltage gradually from zero at
primary winding.increase the voltage gradullay till the
full load current flows in the secondary.The voltage at
which full load current flows that voltage is the impedance
voltage of the transformer.This is required for short
circuit calculations.You can find on the transformer name
plate as Impedance voltage or percentage impedance
| Is This Answer Correct ? | 27 Yes | 5 No |
Post New Answer View All Answers
HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.
What are the application of filter?
I use 20 nos led tube 4feet, in pathway 100mtr approximate, so what size cable i use for lighting
what is the carona effects meaning in HT line transmmission system
operation of diesel generator
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
what is W.T?specify the acceptable range?
Can we Co-ordinate relay in Load Break switch?
Why is a synchronous motor always star connected??
how to select fuse rating for a 3-phase motor ???
i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors
why we use single core 630mm2 cable for transformer secondary side
How cmd is calculated in case of energy neters