Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Are you connected Transformer neutral eathing with it's
body earthing or earthing met of switch yard.? Yes or No ?
why ?

Answer Posted / prabhat misra

in this case transformer neutral is solidly grounded or it is connected to separate earth pit not with switchyard grid as to overcome any of the fault of switchyard equipmenht and also to protect the switchyarsd equipment from any of the internal fault of Transformer

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

to hook up ten 50 amp rv pedastels at a lenth of 600 feet from the service what size will my service need to be and the size of wire will I have to run to each pedastel in series??????

2092


Why is negative feedback invariably preferred in closed loop system?

2312


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

1998


i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?

2038


what is mean by drives?

2016


What is the meaning of dedicated earthing?

2171


what is the criteria for selection of conductor used for ehv ac electrical dischrge

2100


How to decide whether A / B / C / D curve type MCB should be used?

2301


What is the method of estamating of cable, CB,MCB ?

2174


A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.

2114


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1907


What are the conditions to be satisfied for parallel operation of dc generators?

1097


Please brief what is sinewave

2151


Can anyone please give me the parameters , formula needed to calculate the circuit breakers for building services.Thanks

2141


Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT? 

1962