What is GIS Substation and how it operate? where these type
of substation installed?
Answer Posted / purushotham
GIS sub station means GAS INSULATED SUB STATION in this the
entire i.e CB's earth switch, CT's and PT's all are
surounded with sf6 gas in eclosed and this is the very easy
to operate and easy to maintenance but cost is high but it
is very convient where the land cost is very high constrint.
| Is This Answer Correct ? | 7 Yes | 4 No |
Post New Answer View All Answers
What is the count of hvdc transmission lines in india?
Can anybody just suggest about the scope of Electrical design with ETAP software?Just guide me?
What is the effect of pi controller on the system performance?
how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.
Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?
if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer
Single phase and threephase power calculation
what is automatic voltage regulator?we can control the vlotage by using fuzzy controller in matlab?why we go for fuzzy?
What does a Bode plot tell you?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
what is meant by 2 within a star in a voltmeter dial?
What are the basic elements used for modeling mechanical rotational system?
why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
3 phase induction motor connection star or delta while using ac drive motor is .75 to 5.5 kw