transformers parts & function of each parts
Answer Posted / rajasekhar
Transformer main parts :-
1)BUCHHOLZ RELAY: it is avery sensitive gas and oil
operated instrument which safely detect the formation of
gas or sudden prssure inside the oil transformer.
2)CONSERVATOR: it is used to provide adequate space for the
expansion of oil when transformer is loaded or when ambient
temprature changes.
3)SILICA GEL BREATHER: it sucks the moisture from the air
which is taken by transformer so that dry air is taken by
transformer.
4)DOUBLE DIAPHRAGM EXPLOSION VENT: it is used to discharge
excess presure in the atmospher when excess pressure is
developed inside the transformer during loading.
5)OIL LEVEL INDICATOR: it is used to show the oil level in
the transformer.
6)winding temprature indicator: used to show the
temprature of transformer winding.
7)RADIATORS: these are used for cooling of the transformer
oil.
| Is This Answer Correct ? | 81 Yes | 25 No |
Post New Answer View All Answers
how line turns ratio changes in 3 phase with change in connection
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?
Star Delta Diagram with full description
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
When will you multiply and devide with derating factors to the actual value while sizing the cable?
sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in
how to check ac servo motor
After completing iti in electrician, how can i get certificate of electrical supervisor? What ia requirements. For it?
How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
How can get elongation of 2 k.G aluminium, if elongated aluminium dia is 2.5 mm?
How to findout raw or ups power? its not indicated in socket,
why the voltage and current in a long transmission line are called travelling wave?