Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are 3 factors when selecting a contactor for a job?

Answer Posted / shubhanand athalye

1)contactor current rating and duty (Eg AC-1,AC-3 etc)
should be suitable for load.
2) Contactor coil voltage shall be suitable / available.
3) contactor coil burden shall be minimum.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between multimeter

1973


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2669


HOW TO REDUCE POWER PLANT AUXILIARY POWER CONSUMPTION?

3421


How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15

3268


USE OF 8 WAY PAN ASSEMBLY

1967


Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in

4741


Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?

2090


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18451


how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............

2087


What is different between resistance grounding system and resistance earthing system?

1161


How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator

2053


what are the tests comes under the type test, what tests comes under routine tests.

1475


What is the minimum underground tank size capacity considered for firefighting purpose?

1965


How to measure the Harmonic Distortion of UPS ie THD?

2359


what is the difference between dry and wet type of 132kV terminations. which one is durable

2007