Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If you touch power transformer........ Then , in your body
current will flow or not...?

Answer Posted / jagadeesh

no current will not flow because the transformer was earthed

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?

2329


what can be the causes of capacitor start motor having a higher current that its actual

1965


WHAT IS THE FUNCTION OF SHORT CIRCUIT MAINTENANCE CT

2439


Differnce between negative Pahse SequenceFunction and unbalance Function?

1736


Why CBCT rating is 50/1A

2850


After completing iti in electrician, how can i get certificate of electrical supervisor? What ia requirements. For it?

1811


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2580


how u select control transformer for a mccb panels or any panels?for expample we hav 440 volts maim supply and control volts is 230v?

2163


what is solkor relay and which condition it will act?

3352


Whata are the types of Cables?

2142


WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?

4382


If UG power cable both ends are to be earthed or what? If not why?

1936


why electron produce magnetic field when it is in motion?

2140


Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

2175


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2363