Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to select the Cable size for 550 Amps Load without
seeing the cable Catalogue?

Answer Posted / syed masood

t he cable size depends upon the ams rating but the cables size defined standard value the ams rating enclosed this values some values 2.5,4,6,10,......630
first you have to know full conductor size standard value
then you calculate cable size depends upon the ams by using this relation cu=2-5ams per sq.mm
al=1.2-2ams per sq.mm
4 guage for 125-150ams convert guage into mm
from kadayanallur syed masood electrical engineer
national college of engineering

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????

2331


I am abt to give IOCL intrv.Plz sir guide me for IOCL intrvw (Electrical).Which subject to be consider. questions are generally asked from which subject.Plz help me out.

1945


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1821


What is a slack bus?

1086


What is stepper motor?

1219


what should be the no load current for 3 phase ac motors ranging from 5 kw to 1000kw?

1745


I want single line diagram for AMF & DG syncronizing panel

7116


A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

1167


What is safety of Ht panel

1608


Why are short circuit ratings always 16kA,25kA,36kA and 50kA.Who has fixed these?

4224


what is basic difference betmeen normal & flame proof motor??

2104


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1912


EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.

1968


How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

1710


What is meant by turbo alternators?

1131