Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is output of Thermocouple at 25 deg c

Answer Posted / mohammed abbas

Itis depend upon the sensitivity of the thermocouple used
because the different combination of alloy is having
diffrent sensitivity like.
1,copper/contantan =0.039mv/deg
25deg c=0.915
2,Iron/contantan=0.52mv/deg
25deg c=13mv
3,Platinum/rhodium=.05mv/deg
25deg c=1.25mv

Is This Answer Correct ?    13 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?

2056


HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with

2019


Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com

2222


What is the working principle of the magnetic meter?

1060


how to measure draft pressure in transmitter pl. give its single line digram

1943


Why do you want to work here

2264


How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?

2546


the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1634


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1652


What is the advantage of using locally fabricated hook ups over Pre fabricated hook ups in process instrumentation?

1979


How is PH sensor works ?

1917


what is a half wave, full wave, and bridge rectifer.

1714


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5399


What is instrumentation measurement?

1063


Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,

1630