Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

motor and transformer working with same principle so why
motor rotor was roted and transformer not roted

Answer Posted / jitender

Its simple as the output from motor is mechanical form but the o/p of X-mer is in electrical form.To get ant o/p from any system there must be the relative motion b/w the tow parts of motor.

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Working of microwave oven?

2303


We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks

2105


the typical output of a solar cell is........

2415


If we have 11 kv RYB Phase single core cable near about. Then wht effect and losses

1933


how many load we can take for lighting

2324


11KV AND 22KV NETWORK KW CAPACITY IN RING AND RADIAL?

2053


How RTCC panel is working and give single line diagram for RTCC with transformer?

3145


how to remover corona effect and hysteresis losses from contactor

2070


how many current required for hypo test

2042


i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value

1992


what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.

2259


How to calculate the size of earth cable to earth the neutral of UPS ?

1991


why is control bus bi-directional?

2211


excitation limit of an excitor

2101


what reason of line current and phase current in star connection and line current and phase current not equal in delta connection?