identify the components of the tube light and explain how
they function???wat is inside the fluroscent tube???how it
works???

Answer Posted / anandb

major parts of fluroscent set are FLT,chock,starter and
frame.when supply is giver the chock is applied with ac
voltage through starter.(supply-chock-starter-lamp holders-
again supply.starter close and open when voltage across it
is sufficient to heat or cool the bimetallic strip
respectively. when the current through the chock is made to
zero due to opening of starter the voltage across the chock
is enormously high as v= L.(di/dt).
this hi vtg s enough to start ionization of noble
gae(Neon). the closing and opening of starter and hi
voltage induction s continues till the discharge by
ionization takes place completely... Once the ionization
starts the discharge takes b/w the elements of the FLT
there s no need for starter and chock.The ckt s closed
through the FLT.

Is This Answer Correct ?    9 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What we mean by vintage of an engine+Generator?

1589


Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.

1963


mention hazard experienced during installation

1526


How to set the relay,,??

1621


What is the fault or needs to be done when frequency in ac drives is not changing?

1202






what is RFID? thire application;

1526


Define bibo stability.

651


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1289


what is subtransient , transient and steady stateac components

1711


What is the resistance of the field winding of a d.c. Shunt generator kept low?

626


How many devices can be connected in one zone of FACP

1789


how to select energy meter? have any calculation?

2378


Why the standard of ambient teperature mentioned as 40 degree celcius in machines.

1451


132/6.6πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› πš—πšŽπšžπšπš›πšŠπš• πš‘πšŠπšœ πš˜πš—πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš πšπšŽπšπš’πšŒπšŠπšπšŽπš. 𝙸'𝚟𝚎 πšŠπš—πš˜πšπš‘πšŽπš› πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› 𝚘𝚏 6.6πš”πšŸ/415𝚟 πšŒπšŠπš— 𝙸 πšŒπš˜πš—πš—πšŽπšŒπš πš—πšŽπšžπšπš›πšŠπš• 𝚝𝚘 πšœπšŠπš–πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš 𝚊𝚜 𝚘𝚏 13/6.πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš›?? π™Έπš π™½πš˜.. πšƒπš‘πšŽπš— πš πš‘πš’??

573


hi can anyone pls tell me the eee interview core questions asked in l&t

1543