Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why is the vector group analysis done in transformer tests

Answer Posted / pratik

It is to be carried out to check whether the transformer
under test is suitable for parallel operation with another
transfomer having same vector group and voltage ratio but
difference in KVA rating.

Is This Answer Correct ?    192 Yes 35 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what can be the causes of capacitor start motor having a higher current that its actual

1957


List few applications of d.c series motor?

1117


WHAT IS THE MEANING OG (li = 7 In)

2181


If Polarization index of motor 8.75 at 500volts of medium voltage 4.16 KV motor what this mean winding good or bad pl answer if any reffrence book give me the link

2109


I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?

3250


what is the purpose of shading ring or shading coil in electrical equipments.

4459


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2093


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2213


WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?

2211


What is the diff. between single compression and double compression gland

1977


What is knee point voltage of transformer?

1123


How the annunciator works ? How to do its wiring

2285


what is cascade speed control device?and how this device control the speed of motors?

2138


If any cable burnt how can we identify it burnt by high current of high voltage? 

2433


Write the force balance equation of ideal dashpot element.

1323