why table fans rotate clockwise .while ceiling in anti
clockwise?

Answer Posted / amod singh

because of
1- in table fan stator is fix and rotor moving
2- in celling fan stator moving and rotor are fixed

Is This Answer Correct ?    13 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between the transmission line and distribution line?

661


what is the use of piston rings in the engine used for a generator...........

1687


orifice sizing how done, checking & selection

1389


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

1567


what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?

1816






This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

1999


How you will determine the volume of oil in a particular Distribution transformer.

1437


plz send me the syllabus or any sample paper for engineer trainee recruitment if any,on ravinder911@yahoo.com

1690


How much kv gas generator is needed to run 2 hp and 1 hp airconditioners, plus a refrigerator and 4 Tvs

4393


can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?

2792


how are reversing the direction of dc motor

1193


State The Difference Between Generator And Alternator?

665


why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??

1526


sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah

3288


What are the basic elements used for modeling mechanical rotational system?

612