Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why HT voltages are expressed in 11KV,22KV,33KV and so on? (ie
in times of 11)

Answer Posted / meenakshi

every1 say the reason is form factor 1.1....but the actual
reason is,according to the international stds, for every
100V, 10% of voltage is added for the compensation of
transmission loss.

Is This Answer Correct ?    10 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Installation method of self treated earth electrode.

2114


How can ou verify the size of conductor 50Sq.mm ACSR

1994


where rlc series ckt used?

2242


How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations

2172


WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?

2036


what is Fault level? why it is calculated? how will u decide same for our plant?

2119


What do you understand by external characteristics of a d.c. Generator?

1158


what is high - pot test. what's its use?????

2234


what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?

2219


how to determine the inrush current of a transformer

2662


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2176


what is difference between cpp electrical system and refinery electrical system

2353


Define availability (operational)?

1209


What happens if i apply 500V to 440V rotary Switch ?

1887


What is a DC series motor?

1290