how pressure reduce through pressure control valve? suppose
we have to reduce 20 kg pressure to 10 kg pressure , then
what we do ? open the valve or close the valve , initially
it is 20 % is upon ( for ur knowledge ).
Answer Posted / daxish_02
If pipe size is same before and after so this answer is correct..
basic fundamental behind the general formula that is
pressure=force/area......ok
here pipe size is fixed...ok
assume 20% valve open....than area of pipe cover after the valve is more so we get some pressure..
assume that valve open 40% so area of material flowing through valve increase so pressure decrease after the valve.....
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
How to Calibrate Vortex Flow transmitter in field
What is force balance principle? State some of its’ advantages.
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.
A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
selection of the zener barrier for the hazardeous area zone 0
what does it mean an active front end in vfd plz explain it briefly
What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?
How to decrease opening & closing time of on/off valve?
WHAT IS THE CAM POSITION IN CONTROL VALVE POSITIONER ? WHY IT IS USED?
What is the difference between working pressure and calibration pressure of a control valve
What is defferent betwen ESP &PCP PUMP .HOW IT IS WORK?
How do bending tubing provide better measurement than using tubing fittings such as elbows?
what is the criteria to decide conductor size of a cable ?