what will happen when square wave is fed into input side of
3kva transformer and what you will get on output side.
Answer Posted / pallab phukon
if square wave is fed ,then there will be harmonics in the
transformer,which may cause overheating and may even burn
the transformer..
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
How to checked frequency drive output voltages?
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
what are your career plans upon completion of the programme and the relevance of recity generation to your professional development?
why we have to particulary use ACB for below ratings,even available of MCB,MCCB with that range ?
how to enter inverter parameter? without manaual?
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????
what is per unit calculation?looking for simple and strong explanation thk u
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
how to determine motor size for a fan application?
Is it possible to measure the voltage of a battery from a single terminal?
What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer
What is cross over distortion? How it can be eliminated?
what about SAP/MRP regarding manufacturing of electric motors and all drives?