Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If we connect the capacitor banks for DG set for maintainig
the power factor, it will effect to alternator
windings??????????

Answer Posted / gaurav khanduja

we will not have to connect the capacitor with the D.G.
because D.G. work on the principle of AVR(Automatic voltage
regulator)and AVR work always lagging PF. if we connect the
capacitor then it gives leading P.F.And O/P voltage of D.G.
will be vary so we never connect the Capacitor with the D.G.

Is This Answer Correct ?    15 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2492


Pleae send me last 5 years of Question book about RRB chennai.

2274


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

2253


how to find the multiplication factor for digital energy meter and analog energy meter

2195


with help of neat sketch explain principle of TIG welding process

1943


how can i get the formula to find out the cable size if i know the load of main fuse protection.

1928


A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

2574


how can get electrical "c" licence.i am complited in DEEE.PASSING YEAR OF 1993.WORKING IN PVT COCERN LT LINE.PLEASE ADVISE ME .CELL NO 9994786021

1937


Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?

2240


why lightning arrestor are made in two stack of insulator but why not cvt

2061


What is the comparison of PILC and XLPE cable

2103


what is the step by step formula for calculating bus bar phase and neutral size of a panel board.suppose the incomer of panel board is 100A..???step by step answer please

3730


What is the formula formula for Busbar sizing and what are the things to be consider for Busbar Calculation?

2531


what happen as when voltage drop(or may decrease) ? in case of atomic base theory?

2014


Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m

5183