a 3 phase slip ring induction motor is wound for 4 poles on
stator and 6 poles on rotor; when 3 phase balanced voltage
source at 50 hz is applied to motor it will run at
a)1500rpm b)1000rpm c)750 rpm d)zero rpm
Answer Posted / netserab
first v 120f/p i.e. when 120 constant
f given ferquency
p is number of poles
then we have 4 poles on the sator and 6 poles on the
roter 120x50/3/2=1000
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
Explain RLC circuit?
what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.
What is “pu” in electrical engineering?
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????
What is measurement?
Explain using drawings what is reverse PID action w.r.t PID controllers.
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
what is mean by drives?
Let me know that how i calculate the alternator sub tranciant reactance and tranciant reactance.
As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
why the pf of semiconductor device is improved the electrical devices
What is the difference between AC and DC injection methods for rotor earth fault protection
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?