Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What happen if 1200KW/1500KVA alternator runs at no load
and high R.P.M.for one minute?

Answer Posted / subodhkhivsara

If prime mover runs very high speed (without any control)
within a fraction of second rotor damaged and after that
Excitation system damaged.It will goes very dangerous
mode.So Never run Alternator without control.

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Do you need any help with FEWA Electrical Supervisor exams?

983


Which standard we are following earthing resistance test

1390


how current is reverse from its normal direction during the fault?

2433


How o select the electrical fuse?.What are its characteristics.How to select the material od fuse?

1944


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2084


Explain the propagation of harmonics in the network and influence of phase angle of harmonics.

1947


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

1049


What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning

1895


What are the disadvantages of autotransformer?

1099


HOW TO CALCULATE EARTHING SIZING?

2133


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1751


Testing report of Earthing of 3.15 MVa PTR.

2561


What is the actual meaning of thermal power efficiency ?

2133


Sir 33kva 2 transformer load 900 amp calc 1800 amp mana jayega

1813


What are the uses of lead compensator?

1158