Answer Posted / vinod
relays/ pressure switch/temprature swicth etc. have NO & NC
contacts
NO (Normally Open) means the contact of the relay will be
open during the relay coil de energised condition and
contact close when relay coil energised condtion.But in
thermal switch NO means swich conacts open during the set
temprature and close when the temprature exced the set
value.
NC (Normally Close)means the contact of the relay will be
close during the relay coil de energised condition and
contact open when relay coil energised condtion.But in
thermal switch NC means swich conacts close during the set
temprature and open when the temprature exced the set value.
NO & NC can be used in control/power circuit depends on
requirement.
| Is This Answer Correct ? | 22 Yes | 4 No |
Post New Answer View All Answers
What is difference between insulating medium and fault current interruption medium in a switching device.
how can we select the type of wire.what factors we have to look on it , do we have some formula to calculate it. please guide me on it
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
how to select diiferent power transformers of same capacity on no load loss and full load loss by economical point of view.?
In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?
what could be the RMS value and average value of a 4 phase sine wave?
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
How we calculate DC inducation moter Amp? Sir pls give me formula......
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
how to calculate transformer load?
how to select the no. of brushes in a lap winding?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
How much load can be taken for chiller from 1500 kva transformer
Define unilateral circuit?
If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?