Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Two electronic energy meters are connected to seperate
phase wires, but connected to a looped neutral. Are these
going to function correctly?

Answer Posted / karthik

yes, if the the 2electronic energy meters are connected
under the same distribution substation it will work, but if
the 2 energy meters are connected in diffrent substation it
will not function properly, becuse neutral only carrying
return current for the single phase loads, if u connect
your elcb getting trip.

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2058


Define open loop control system.

1052


why cable i burning without tripping. how can protect led street lights

1502


how we start 40w tube light with 4 diodes,2capacitors,1 choke and without starter.(a product avilable in market which lights burnt tube lights also)

1993


What is the difference between AC and DC injection methods for rotor earth fault protection

2146


Apparent power is expressed as V * I(Conjugate). Why not in V * I ?

3850


Define settling time.

1101


Write the force balance equation of ideal spring element.

1204


list the advantages of RCCB over other circuit breakers?

1665


What is the difference between rated and per unit in transformer?

2128


What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act

1976


details of oil cell size of Breakdown voltage test of tranformer oil details as per Standardswith mushroom electrodes?

1826


What are the two types of compensation?

1042


How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer

1701


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1828