What is the difference between RMS and average value
Answer Posted / padam singh
RMS value is the root of the average of the square of the
instantaneous value of any wave. Being the squared it comes
always in positive value. It plays important role in
representing the value of sine wave (Mains voltage
specifically).It's value for a sine wave is equal to Peak
votage/sqrt(2). However average value is the simple average
of any wave. It comes positive for positive half and
negative for negative half of a sine wave. It's value is
Peak voltage/Pie for one half only and zero for a complete
sine wave. Generally AC Voltage is represented in terms of
RMS value.
| Is This Answer Correct ? | 42 Yes | 9 No |
Post New Answer View All Answers
what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?
HOW WE KNOW IN PHYSICALLY THE CONTACT SURFACE OF A VACUUM INTERRUPTER IS GOOD OR GOING TO DAMAGE IN A VCB AFTER ABOVE 500 TIMES OPERATED.
How it can worked plc based electrical system And which type of software using.
i completed my DEEE. and i want to electrical c license. how to get it..?
if 12v battery get discharged for 2 months after if we put charge it will charge again?how much time it will take to charge?
What is the function of a neutral reactor.
I am doing apprenticeship training at HT switch yard in NLC. How can i get electrical c license. ??? What r the rules for getting it as an apprentice? ??
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
how to set the time in digital timer ?
Why does the radius of armature is less than the radius of pole shoe?
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
WANTCONTACT NUMBER & EMAIL/ WEBSITE TO CONTACT THE SECRETARY,MADHYA PRADESH LICENSING BOARD(ELECTRICAL),K- BLOCK,3RD FLOOR,SATPOODA BHAWAN,BHOPAL
Why arc quenching is used in Diode ?
What is difference between Over Current & Earth Fault protection?
Difference between a pilot wire and a normal conductor?