Answer Posted / sajid
you are very correct..but u forgot one main thing..the scan
for PLC is lessthan DCS..
scan time for PLC is 100ms and scan time for DCS is 500 ms..
so that in indusrties they are using the PLC's for critical
operations along with DCS..such as shutdown or emergency
operations..
Regards..
SAJID
INSTRUMENTATION ENGINEER
Is This Answer Correct ? | 14 Yes | 2 No |
Post New Answer View All Answers
How is automatic reference junction compensation carried out in temperature recorders?
How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.
What is first echo & echo window in radar type level transmitter?
Name different parts of a pressure gauge.
What is Positive Calibration and Negative Calibration?
how to calibrate load cell
Hello to all....I am an Instrumentation Graduate and i am passed out in this year only.. I am unable to find the job in my core instrumentation.. so any boby tell me how to and where to search the job....please...and also tell me i there are any courses offered in the instrumentation stream so i can do it... you can send your suggestions to my mail-id i.e Ganesh20084u@gmail.com ... please..
How u will setup SPI(2007) on Citrix Server (Thin Client Mode)? Plz Justify?
Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com
The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?
Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com
what does the ratio 800-400-300-200/1-1-1-1-1 in the specification of current transformer indicates?
where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com