What is the purpose of Rotor earth fault relay and How to
test the Rotor earth fault relay in generators and What is
the procedure?.

Answer Posted / mani_mc2006

1.one earth fault will not affect the generator more. but at
the same time if another earth fault happened it's dangerous.
2.We can test this relay by using Resistance Pot.
3.Apply the Aux supply and connect the resistance pot across
the terminals where we taken reference from the generator.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m

4341


132/66kv sub-station procation ?

1712


WHat is the general checks required for Dry type transformers

1647


PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com

1610


Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response

2418






What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1236


why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?

1412


where was current transformer protection units used and why??

1540


I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?

1526


EXPLAIN USE OF ROCKING ARRANGEMENT IN ELECTRIC HEATING?

1378


can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.

1375


Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer

3186


why the neutral point in connnection oscillates?

1804


Transformer cores are laminated in order to A simplify its construction B minimize eddy current loss C reduce cost D reduce hysterisis loss

2834


Differentiate between digital phase converter and ordinary phase converter.

757