why DC motor body is plain cover but AC motor is different
like finse?

Answer Posted / avd

In AC motor load current flows in stator and causes heating
of stator. Hence to cool it down fan is provided which
cools the body. To increase area fins or plates are there
on body.

In DC motor load current flows through armature, causes
heat generation in armature. To take out the heat you need
to cooldown armature. Stator cooling is not required, hence
plan body is okay.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Whats the minimum value for I.R. that can be allowed for HT & LT alternators for operation?

3417


Give the topology of current amplifier with current shunt feedback?

716


what is the formula of starting current of 3phase and 1 phase motor???

1587


What is the function of the generator exciter?

925


what will happen when the dc supply is given to the capacitor?

1012






what is difference between cpp electrical system and refinery electrical system

1750


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1574


CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??

5077


what is the purpose of silicon dropper used in battery charger?

6670


what is the constructional difference between a power transformer and potentian transformer?

1269


what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation

1469


how meger function

2425


An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?

1630


What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??

1397


state the disadvantages of carbon filament???

2377