whats the diff b/w mpcb and mcb?weather it trips on single
phasing or not.
Answer Posted / atul
The question is still not clear to me......
as.
1). MCB protects from overloadin,short circuit..
2). MPCB protects from overloading,short circuit and motor disconection...in all of the above cases it will trip....nd moreover the main dfrnc btwn mcb nd mpcb is dat mpcb is provided with auxiliary cntacts(normally open nd normally closed)basically mpcb is connected with cntactors to provide two cmponent starting.......nd mpcb ranges r variable it can be set from frnt bt mcb is set for a fixed rating....
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
how does the rotating m.m.f is produced in the 3-phase induction motor and how the poles are created in 3-phase induction motor ?
why lightning arrestor are made in two stack of insulator but why not cvt
I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE
What is maximum power transfer theorem?
Why Water motor is not taking a load or pressure while everything is correct. (Note: Motor running properly)
How to calculate impedance volt in Transformer?
BSNL TTA EXAM QUESTION
What is the disadvantage in proportional controller?
What are the factors which influence the choice of specific magnetic and electric loadings of a synchronous machine?
what is the function of statics switch in ups and tell me parts
what r substations?what r there work?why voltages r incresed and then reduced during distribution of power
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.
what is the difference between directional & non directional earth fault with example please explain.
why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?
Please explain me abt PQ diagaram in the power sector.