what is the difference between the electrical and
electroncis

Answer Posted / mohan

electrical means which works on AC voltages(220v to 250v),
ex; fan,transformers

electronics means which works on dc voltages(110v dc)
ex:computers,laptops,mobiles mohan.burra@gmail.com

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1491


hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.

2311


Why we use duplex coil and hook switch in telephone system?

4551


What types of CMOS memories have you designed? What were their size? Speed? Configuration Process technology?

3114


what's the difference between 'shaft power demand' and 'BHP' , when we consider electrical load list.

1060






impliment (AB)`+C to transistor representation

1306


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

1677


IN dc capacitive reactance is??

907


what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?

1764


Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.

1384


When lag/lead/lag-lead compensation is employed?

703


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating

1884


for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?

588


Dear Sir I am living in Jaipur Rajasthan  now I did complete my b tech degree in electrical engineering in 2012  Sir how I gate certificate of competency for electrical supervisor

1563


How i can calculate current of cable according to ares?

1395