Answer Posted / dev
in fan, inuction motor is used to drive the fan load.
the regulator of fan consists no. of resistance
contact...it changes the the resistance of ciruit.
in starting resistance is kept high for high starting
torque, at that time speed will be low..after this instant
resistances are slowly cut out...and speed will rise..
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
what will be the min and max voltage flow from neutral to earth?
How is the percentage impedence of a transformer fixed at design stage???
when we have to purchase the transformer by own i.e how much load will preferred HT connection?
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
What happens if the series current double?
What is Surge Capacitor? Why it is require in Generator Circuit Breaker,inspite of surge arrester?
How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Explain how you intend to work under pressure to meet up with deadline target?
what is the voltage between earth to neutral in lift.
If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive
Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.