Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain Difference between Bech set and operating range of
control valve

Answer Posted / rakesh kumar.n be

if u do the adjustment in the string at the actuator, or
compress the spring, u will get the opposing force to move the
stem in the control valve that is called bech set .it depents
on the control valve. mostly foe small valve we use 3-15 psi
and for medium we use 6-30 psi .thanks

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

use of split range ? where it is used ? in which control loop it is used ?

1925


How to change dcs card in online. (Dsc is maxdna)

2629


how to calculate range of level transmitter?

2258


key exchanges in wpa,wpa2,tls

1863


List three types Level Switches with their working principles

2065


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1913


Explain the difference between plc and cnc?

1010


i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.

1984


What are the error values can accepted in flow transmitter calibration?could u give any formula for this?

1844


How many ohms are required for proper earthing?

1042


Describe a time when you anticipated potential problems and developed preventive measures.

2861


Basically iam Instruemntation Engineer, but Iam interested in Instruments design engineering, so plz guide, is there any course, training or Softwres to become Instrument design engineer??.

1996


CONTROL VALVE OPERATING IN MANUAL BUT NOT IN MANUAL. WHAT SHOULD BE THE PROBLEM ?

1847


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2679


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2205