Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we Specify Transformer rating 433 V Instead of 415V
?

Answer Posted / ash

433V is the no load voltage. that is when the transformer
is supplied at its HT side but without any load connected
to the LV side.

Is This Answer Correct ?    18 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

3373


How to decide DO set rating of Transformer?

1649


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1713


Name one of major transformer company in KSA ?

1199


when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?

2074


what will happen if ac and dc supplies given

2124


how does a shunt reactor maintains the bus voltage???

2058


can we synchronize star system generators with delta system transmission line ? and how ?

2833


What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)

1561


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2177


Power Factor Correction Panel (Manual & Automatic)

2219


can the measured percentage error during calibration of single phase energy meter be negative?

2401


Explain in brief description about the operation of DG sets.

2440


I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?

1658


What are the main advantages of bode plot?

1246