why table fans rotate clockwise .while ceiling in anti
clockwise?
Answer Posted / k.prakashchandra
Ceilig fans circulate hot air from fireplace upwards in
clockwise rotation during winter and the opposite in summer
for cooling, with reversing switch.In India they are for
cooling only ,hence only anti -clockwise rotation.By
reshaping blades/paddles, they can made clockwise.
| Is This Answer Correct ? | 3 Yes | 10 No |
Post New Answer View All Answers
What is the types of HT motor testing
what should be the no load current for 3 phase ac motors ranging from 5 kw to 1000kw?
In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?
Hello to all, Please someone can send me HPCL ELECTRICAL Engg. Sample papers to me? Its urjent....my email address is.... raviasiapacific@gmail.com
how to calculate the magnetizing current of ct ( 800A/1A) for Relay 64
how to store the thunder power?
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
what happen if the supply is given to the stator of the 3phase induction motor with out assembling the rotor ?
what is the difference b/w pvc cu conductor and cu breaded wire..?
WHICH SIZE A.B.CABLE IS USED FOR 11KV.
what is metering cum synchronizing panel and how it is used?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is the significance of integral controller and derivative controller in a pid controller?
EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks