Answer Posted / ravindra
pf tells that how much amount of power delivered by the
source from their total power. in ac ckts it is Cos(q)=p/vi,
ac ckts have v and i both sinosoidal fuction so it comp up
cos q but in electronic ckts cos q never used . so pf=
delevered power/total power , formula used for electronic ckts
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What is ST and specify its range of voltage.
in electrical control panel. how can i choose the cable rating. (example - 11kw motor, 18-25A mpcb}
I am going to appear for the RRB Chennai junior Engineer online exam. Please send me the previous exams question papers (also solved) to my mail id: rrkhandhar@yahoo.com
what is magnetizing current test in power transformer
we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
What is servo motor and what are different types of servo motor
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?
What kind of Neutral CT can be placed in 11/0.433KV transformer to be used and what are its specification?
Why is better to have a minimum ceiling voltage of 250% than 160%?
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
is it possible to start a motor in felid connected to a remote mcc
how did the testing of protection relays done through current injection
We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.