what is the dp across a orifice plate & how much is
permanent pressure across an orifice plate.
Answer Posted / ali
dp(differential pressure) the pressure across dp can not permanent it changes with change in up stream pressure and also pressure change to down stream and velocity also increase at down stream side of orifice plate it is called differential pressure.
Is This Answer Correct ? | 3 Yes | 10 No |
Post New Answer View All Answers
how to calibrate 0- 150 psi presure gauge by dead weght tester
List three types Level Gauges with their working principles
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
Describe the function of Accumulator into the Pump
How to calibrate Field bus transmitter? procedure ?
if in a level tx height is given, how u calculate the ranges of the tx?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
How to decrease opening & closing time of on/off valve?
anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
What is difference between radial vibration and axial vibration explain in detail .
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com
I want to measure and control level in tank of size 10*5 filled with gasoline, so plz give me the solution with clear details. how to select transmitter and sensors.
What is frequency factor in massflow meter? When using frequency output?