Can anybody explain Why starters are not used for motor
starting in industries?
Answer Posted / pillay
Is your question correct? All motors must be started with some
type of starters what more if they are used for industrial
purpose.
In addition to provide a safe mean of starting and stopping
the motor it should be able to to protect the motor itself.
With the help of a starter you can provide overcurrent and earthfault protection unauthorised starting unwanted stopping
and you can plan your starting and stopping as desired.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
and gate circuit diagram,amplifier circuit diagram
what is the minimum (Common factor) insulatin resistance of the following a, 4mm sq wire b, cable from 50 mm sq to 800mm sq
What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
why we not used 11kva as a direct our electrnics component.
what clearance required for 4.5 mva dry type transformer?
Why colled 440V to 3-phase supply.
In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????
If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)
How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors
What is the difference between line drop and percentage line drop?
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,