why the starting torque is high in dc series motor..
Answer Posted / nilkanth tailor
COZ, TORQUE IS DIRECTLY PROPORTIONAL TO THE SQUARE OF THE
CURRENT...SO THAT THIER IS VER HIGH CURRENT PRODUCE IN THE
STARTING OF DC SERIES MOTOR...AND IT IS DIFFICULT TO
CONTROL HIGH CUURENT...SO GENERALLY D.C. SERIES MOTOR
GENERALLY USEB IN TRAIN...CAUSE TRAIN REQUIRE HIGH STARTING
TORQUE...DUE TO HEAVY LOAD
Is This Answer Correct ? | 13 Yes | 2 No |
Post New Answer View All Answers
ELECTRICAL ENGINEER TEST IN FEWA ANY ONE HAVE KNOWLEDGE ABOUT THIS?????????
What is the function of Governor in Hydro Power Station? What is the Function of Lightning Arrestor Voltage Transformer (LAVT)?
how to calculate IR value of 33KV cable ??
Purpose of providing neutral isolation panel for parallel operation of diesel generator
what is meant by directional earth fault and non directional earth fault? describe both.
what is meant by k-rating in isolation transformer?what is k9, k14 stands for?
What are the types of class b amplifier?
How could I get a certificate of competency as Electrical Supervisor? I have completed By BTech in Electrical this year(2012) for VJTI Mumbai Maharashtra. Is it compulsory to be produced while joining?
How to select batteries required for ups and the inverter if we Known load? And how AH is selected of battery?
Dear all, I want to use Induction motor to open and close a 1 ton door. How much power do I need. Thanks
why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?
Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me
What are the advantages of stationary armature and rotating field system?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?