Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if the t/c o/p is 4-20mv then how plc recognize it
because we are dealing with the 4-20ma in the
plc ????????????????

Answer Posted / altamash

In plc, there is a separate I/O MODULE FOR T/C which already have inbuit converter so we dont have to worry on this,First we have to know complete module of plc.thanx

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calibrate and troubleshooting of leveltroll?

2124


HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?

3456


Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2442


hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v

2162


how to calculate the total flow in square root

2316


I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann

2214


How to Calibrate Ultrasonic flow Transmitter in Field

1205


What is the difference bitween control net scaner and device net scaner

3528


What is solenoid valve? Where it is used?

1040


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

2167


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

3105


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1824


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1414


a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error

2236


TEMPERATURE VARIATION FOR FREQUENTLY.

1984