Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in case of three phase induction motor,when it is connected
to three phase supply,why the magnetic field is rotets
around the armeture?

Answer Posted / dinesh verma

in indction motor, motor windings also plays a very
important role. these are also placed 120 degree apart. so
when you apply 3 phase supply, it forms a magnetic pole in
the stator. as the 3 phase supply is sinusoidal, the formed
magnetic pole starts rotation in one direction.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is it value of power factor is more than unit. whats effects in the source supply

2032


At what speed 1 HP motor can run an electric car of weighing 400 kg?

1520


How can ou verify the size of conductor 50Sq.mm ACSR

1883


What are the advantages and disadvantages of negative feed back?

1079


write down the formula of cable size in RM if current is 50Amp.

1283


how we can calcultae the short circuit level for bus bar

2166


Briefly define and explain the following different types of Pulse Amplitude Modulation (PAM) with some examples. i) 2-PAM ii) 4-PAM iii) 8-PAM iv) 16-PAM v) Quadrature Amplitude Modulation (QAM)

2075


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating

2355


how many parameters can integrate with fire alarm basically ?

1907


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1880


What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?

2269


How to improve fuel cell in a distribution system?

1930


On what basis the the size of Lightning arrester for buildings are selected ?

1597


how to measure earth resistance of a substation

3261


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

2108