Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the concept of voltage & current its relation?

Answer Posted / adi vishnu

Vltage and current are two different vectors wihch
represents in the respect of another vector defining a
specific angle which is nothing but a power factor.Another
is voltage is the potential difference between two points
and and the curent is impression of load which is conected
between these two points.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

2029


List few applications of d.c series motor?

1116


what shoud be strength and weakness to impress interviewer????????

2050


What are the basic components of the feedback control system?

1031


What is called grain-oriented laminations?

1127


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2135


please send previous exams question papers

1810


What is the requirement of grounding the neutral of single phase generators on load? If the neutral is not grounded, what will be the effect?

2091


after how many spot we must chang secondry cable in portable spot welding gun?

1921


Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.

1983


what is the function of capacitor duty contactor in an capacitor panel???

4124


WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT

3149


how to select battery for 15 KVA UPS with formula

2523


there are cam operated switches - why we call cam operated , What is cam ?

1894


how much cable size required for 70 kilowatt load.

1663