Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the industrail measures to overcome ferranti
effect? how would the ferranti effect the power system if
those remedial mearsure arent taken? how often does this
effect occurs in real power system? plz reply

Answer Posted / ranjeet kumar suman

shunt reactor be used to overcome ferranti effect.due to tis
effect the reciving end voltage be greater than sending end
during light load condition....

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS THE FUNCTION OF SHORT CIRCUIT MAINTENANCE CT

2502


dc supply given to dc generator winding.how is possible? my knowledge is saying the winding will burn. please reply.

1417


Dry type transformers

1914


WHY IL=IPH IN STAR AND WHY IPH=IL/1.732 IN DELTA? WHAT IS REASON BEHIND IT?

6456


Refernce currents are to be generated using refernce cueernts how can this be done

2316


in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1882


I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME

1875


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2252


what happen if the supply is given to the stator of the 3phase induction motor with out assembling the rotor ?

1970


pls tel me the electric train traction motors name plate details like rpm,torue,voltage,amps,watts..ect..

2115


why connecting surge unit in contactor coil

1929


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2154


what is the difference between droop mode and ischnorous mode in thermal powerplant?

2705


What are the temperature elements?

1294


Mention the disadvantages of low power factor?

1181