i have calibrate rosemount make level transmitter , wht
can i do ? my tank capacity is 30,000 liter
Answer Posted / vivek
P=H*D gives u dp which sufficent to calibrate transmitter
for value to read 3000 liters is the conversion of scale
from 0-100%
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Which type of pressure can be measured by these elements?
What is the use of each wire in three wire RTD
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
this site is owned by an nonsense
How can we use feedback signal frm rtd for monitoring and in dcs for controlling ,then which type of rtd is sutaible 2 , 3,4wire and why ?
How to convert Differential pressure to flow in TPH
principle of automatic votage regulator
What is the use of temprature compensation?
There are many type of control cable like pair,core,tried, What are defination each one
What are primary elements of measuring pressure?
How to work togather like sov,limit switch,proxy switch and booster in xv