How to calculate the size of the cable? for exp i want to
use the load of 10HP
Answer Posted / charan
fine buddy, what i want is how the manufactures is deciding
that Sqmm of the cable ??
| Is This Answer Correct ? | 0 Yes | 6 No |
Post New Answer View All Answers
is IS says that neutral should be brought to switch box. and this one is a recomended practice
What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP
when the time of backcharging the transformer three phases only enough or three phase with neutral is must.from these which one is the best one.
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
why ct ,cvt should be stored in a vertical position?
Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.
How to select a contactor? How many types of contactors are available
HOW TO CALCULATE S/C,O/C,E/F OF ACB.
Why compensation is necessary in feedback control system?
Why do we perform an open-circuit test and short-circuit test on the transformer?
how to set relay setting? and example calculation...
Where voltage are high and current to be interrupted is low the breaker preferred is:
where is the need for short circuit test for 3 see is required and why? can you explain in brief with application
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Why do we use copper cable for HT Supply and why not Aluminium?