Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how many amps in 1KVA?

Answer Posted / subbu

i am giving example for 3 phase 415 V
P= 1.732xVxIxcosQ for 3 phase
so first we need change the KVA to KW
1kva = 1x.8(pf)
=.8kw or .8x1000 Watt
example:-
V=415VOLTS,3-PHASE,P.F=08
P=1.732xVxIxCOSQ
I=.8x1000/1.732*415*08
I=1.39amps

Is This Answer Correct ?    29 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is allowable ac mixing in dc

2166


Testing procedure of DG alternator stability test

1632


What is an ideal transformer?

1232


How to calculate the phase to phase clearness of HT /// LT bus bar?????

2136


Explain what is rated speed?

1195


how we can calculate power factor in single phase & three phase ?thank u

2049


why any centrifugal blower draw more current in starting. consider id fan and fd fan?

1896


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2298


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

2039


Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?

2197


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1887


what is die electric strnth of transformer ?

2248


what's the requirement of Dy11d0 connection of 3 phase transformer?what's use of it?

8040


What is nichols chart?

1406


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

2007