in the pipe line if the control valve fails to respond to
controller action,by what means we can stop the flow in the
pipe line ?
Answer Posted / ashwin jain
but wat happen if no 1 is there to control
manually..chetanya's answer is correct....
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
what is Best Among SINK Or SOURCE Type Design In Digital Signal, Either Iput Or Output? WHY?Can any one..
how u calibrate pneumatic n motorized c/v?
you are on site,the plant trips,you are approached by operations,what do you do?
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
Can I calibrate the Electromagnetic Flow Meter on line and How.
can we create an interrupt in plc through scada?
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
hi i am eswar i want to know the instrumentation interview questations for eil(engineers india ltd) i have applied for engineer post in eil please help in this.my mail id eswar310@gmail.com
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?
what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.